When the diesel generator set is charged, it will also encounter the problem of not charging into the electricity, so how to solve it? This problem may be caused by a broken fuse or rectifier diode. When the fuse is blown, the power indicator light of the charging machine is not on. After the rectifier diode is damaged, the power indicator of the diesel generator charger is on, but there is no DIRECT current output. Let's find out what the reasons are.
1. The charger transformer of the diesel generator set is burned out.
2.The diode in the diesel generator charger is burnt out.
3. The charging ammeter of the diesel generator charger is damaged.
4.The fuse of the diesel generator charger has blown out.
The method of troubleshooting is to disconnect the charger and the battery connection line, with a multimeter DC voltage block (50V) test the voltage between the two output terminals of the charger, pay attention to the red meter pen is connected to the positive pole of the charger, the black meter pen is connected to the negative pole, found no voltage output. Remove the shell of the charger and check the charging insurance core. It is found that the 60A insurance core is burned out. After replacement, the charger will resume normal charging and the fault will be eliminated. In the charging process of diesel generator set, in addition to their own attention to safety, but also pay attention to the possible faults in the charging process, timely troubleshooting, to ensure the normal operation of diesel generator set.
Jiangsu Meao Power Technology Co., Ltd. focuses on the development and manufacture of diesel generator sets, and has accumulated rich experience in manufacturing and service in this field. As a professional generator manufacturer, MEAOPOWER attaches great importance to product development, innovation and service quality, and maintains close strategic cooperation with famous domestic and international enterprises such as Cummins, Perkins, Doosan, Yuchai, Weichai, Shangchai, Wuxi Wandi, Lillesomer, Stanford, Marathon and so on.
Contact: Ms chen
Phone: +86-18852658865
E-mail: clp@meaopower.com
Add: HaiLing Industrial Park.Taizhou.China