Cummins diesel generator set can not start how to troubleshoot

Today I would like to share with you two reasons for the failure of diesel generators to start, as follows.


One,Plunger parts


The plunger assembly consists of a plunger and a plunger sleeve. The upper part of the plunger has a straight groove and a spiral groove, and the lower part has a bump and a small bump shank. The upper part of the plunger sleeve has an oil inlet and an oil outlet. When installing the plunger sleeve, ensure that the oil inlet and outlet holes are connected to the low pressure oil channel in the pump body, and that the grooves on the oil inlet holes are aligned with the positioning screws on the pump body and fixed. The function of the plunger assembly is to generate high pressure diesel fuel by moving the roller body up and down, and to deliver the high pressure diesel fuel to the high pressure fuel line and fuel injector through the delivery valve assembly.


Two, the oil valve coupling


The oil outlet valve coupling is one of the precise parts of the injection pump, which is mainly composed of the conveying valve and the seat. The conveying valve assembly is installed at the upper end of the plunger sleeve. In order to prevent oil leakage, a nylon sealing ring is installed on the oil outlet seat, and an oil outlet valve spring is installed on the upper part of the oil outlet valve, and then the oil outlet valve is firmly fixed. Fixed. The tightening torque of the oil outlet seat should not be too large, generally 39? 68 n. m. If the tightening torque is too large, the plunger sleeve will be deformed, which will affect the sliding performance of the coupling.


The function of the fuel delivery valve is to quickly isolate the diesel in the high-pressure fuel line from the plunger's upper oil chamber when the plunger stops supplying fuel, and to prevent diesel backflow in the high-pressure fuel line. As the plunger descends, it enters the fuel injection pump.


Generators play an important role in production, so what is the reason for the failure to start a diesel generator set? In general, the generator set can not start, you can refer to the following points to correct. The upper part of the plunger has a straight groove and a spiral chute, and the lower part has a bump and a small convex handle. The upper part of the plunger sleeve has an oil inlet hole and an oil outlet hole, an oil outlet valve assembly, adjusting screws, roller pins, rollers and roller bodies, etc., which will cause poor transmission and lead to oil volume control sleeve, camshaft and oil volume adjustment. The work of the gear lever and pump body was hampered, and the diesel generator set could not be started during routine operations, so these aspects could be examined.


2018071009.jpg


Jiangsu Meao Power Technology Co., Ltd. is an important manufacturer of diesel generators. The company mainly manufactures and sells diesel generator sets with power of 3-3000kW, mobile power station of 24-600kW, Marine emergency diesel generator set of 24-800kW, gas generator set, heavy oil generator set and all kinds of imported series, special series (trailer, static speaker, mobile lighthouse, container, etc.) diesel generator At the same time, we are engaged in generator set maintenance and after-sale service of generator set accessories.