MTU Diesel generator unit precautions

Today, by Jiangsu Meiao Power Technology Co., LTD., internet editor to share about the diesel generator set preventive measures, the details are as follows.


1. The unit should be kept clean, no water leakage, oil leakage, air leakage, electricity leakage (four leakage) phenomenon. The components on the unit should be intact, the wiring is firm, the instrument is complete, the indication is accurate, and there is no screw loosening.


2. Before starting, check whether lubricating oil, cooling water, diesel oil is enough, not enough or bad, should be added or replaced in time. General machine running 250 hours to replace oil, 50 hours to clean the air filter, other maintenance requirements according to the manual and regulations.


3. Start the battery and check the charging voltage and electrolytic level every month.


4. If the temperature of the oil room is not less than 5℃, the heater should be turned on to heat the unit.


5. During the operation and use of the diesel generator, assign special personnel to be on duty, observe the operation of the unit, add cooling water and fuel oil regularly, pay special attention to the temperature, sound, vibration and instrument indication of the unit during operation, and immediately stop the machine for inspection if any abnormality is found.


6. In order to ensure the stable and economic operation of the oil machine and the qualified and stable output power, do not turn on and off the load at will in the operation process.


7. Diesel oil although the ignition point is higher, but it is still flammable and explosive substances, adding must be carried out when stopping. Diesel engine operation process will produce a large number of toxic waste gas, when the unit is placed in the base station to generate electricity, the operator in addition to pay attention to the unit ventilation, exhaust, power generation do not leave in the machine room for a long time, to avoid personal injury.


8. When the generator is running at high speed, do not approach the flywheel, the belt of the diesel engine fire pump, the connecting shaft or stand in the longitudinal direction to avoid flying objects hurting people.


9. Every half a month no-load test once, half a year with load test once, timely check the unit lubricating oil, fuel, water level and battery.


genset (2).jpg


Jiangsu Meiao Power Technology Co., Ltd. is an important manufacturer of diesel generators. Us ao-generator set manufacturers mainly manufacture and selldiesel generator sets, the power of generator sets is 3-3000KW, mobile station is 24-600KW, Marine emergency diesel generator set 24-800KW, gas generator set, heavy oil generator set and all kinds of imported series, special series (trailer, silent speaker, mobile lighthouse, container, etc.) diesel generator Group at the same time engaged in generator set maintenance and generator set accessories after-sales service.