Industry news

What are the specifications to know after the Perkins generator set is started?

After the start of the generator set 8 use standard skills, many friends think that the diesel generator set after normal start do not have to take care of, in fact, this is not right, because the diesel generator set is more likely to break down after the start. So at this time also to carry out regular routine inspection of it, so as to ensure the normal work of the generator set.

2018071003.jpg

The following with Jiangsu Meao Power Technology Co., Ltd. to see the use of 8 standard skills after starting

a. Set the pressure regulating selection switch on the switch screen to the manual position;

b. open the fuel switch, and fix the fuel control handle at the throttle position of about 700 RPM;

c.with high pressure oil pump switch handle continuously manually pump oil, until there is pump oil resistance, the injector squeaky;

d. Put the oil pump switch handle on the working position, and push the pressure reducing valve to the decompression position;

e. Start the diesel engine by hand handle or press the power start button. When the diesel engine reaches a certain speed, pull the axle reduction back to the working position quickly to start the diesel engine.

f. diesel engine starting, the electric key back to the middle position, the speed should be controlled at 600 ~ 700 RPM, and pay close attention to the oil pressure, table instructions (see the working oil pressure value of all types of diesel engine operating instructions), if there is no indication of oil pressure, should immediately stop check;

g. If the unit runs normally at low speed, the speed can be gradually increased to 1000 ~ 1200 RPM preheating operation. When the water temperature is 50 ~ 60℃ and the oil temperature reaches about 45℃, the speed will be increased to 1500 RPM, and the frequency meter of the distribution panel should be about 50 Hertz and the voltmeter is 380 ~ 410 VOLTS. If the voltage is high or low, the magnetic field rheostat can be adjusted;

h. if the unit works normally, can close the generator and negative plant between the air switch, and then gradually increase the negative plant, power transmission.

Jiangsu Meao Power Technology Co., Ltd. focuses on the development and manufacture of diesel generator sets, and has accumulated rich experience in manufacturing and service in this field. As a professional generator manufacturer, MEAOPOWER attaches great importance to product development, innovation and service quality, and maintains close strategic cooperation with famous domestic and international enterprises such as Cummins, Perkins, Doosan, Yuchai, Weichai, Shangchai, Wuxi Wandi, Lillesomer, Stanford, Marathon and so on.