The reason why cummins diesel generator set automatically stops when oil is insufficient

Generator main motor and power is to see it, a good generator, motor and power is pretty good, if the motor generator and power is broken distributor that can repair, can only send the factory repair, generator a little problems generally what if everyone can handle, here is the general small and medium-sized gasoline generator and diesel generator to the problems and Treatment methods:


Why does it stop automatically when there is insufficient oil?


When the oil is low, the oil warning switch inside the engine will ground the primary coil of the ignition coil so that the ignition coil cannot ignite and the engine will stall. Check whether the oil level is standard: the engine is in a horizontal position, spin out the oil ruler, clean and dry before inserting the oil into the port (without rotation), and then pull out, check that the oil level is in the middle of the oil ruler.


What must be done when an automatic voltage regulator (AVR) is damaged and needs to be replaced?


The generator set does not generate electricity, the most common fault is the damage of the automatic voltage regulator, so when it is found that the generator set does not generate electricity, it is often solved by replacing the old AVR with a new AVR. When users do this, they find that the new AVR fails after a few minutes of use, and then complain about the quality of the AVR. In fact, AVR damage is often caused by the user overloading the generator set, resulting in short circuit of the rotor, resulting in AVR damage, so before replacing the AVR must first detect whether the resistance of the rotor is normal (such as the resistance of EC2500CX is 45-50 ohm). If the electrical group of the rotor is abnormal, replace the rotor first and then the AVR.


Long-term storage (more than three months) if not used, follow the following steps:


1. Drain gas from tank and carburetor.


2. Drain the crankcase of oil.


3. Fill new oil to the upper limit of the oil gauge.


4. Close choke and pull the starter handle to the point where resistance is felt.


5. Wipe the unit clean and cover it with carton or plastic cover to prevent dust.


2018071003.jpg


Jiangsu Meiao Power Technology Co., Ltd. is an important manufacturer of diesel generators. Us ao-generator set manufacturers mainly manufacture and selldiesel generator sets, the power of generator sets is 3-3000KW, mobile station is 24-600KW, Marine emergency diesel generator set 24-800KW, gas generator set, heavy oil generator set and all kinds of imported series, special series (trailer, silent speaker, mobile lighthouse, container, etc.) diesel generator Group at the same time engaged in generator set maintenance and generator set accessories after-sales service.