Plug check of radiator of Perkins diesel generator set

The scale should be cleaned thoroughly before checking the radiator of diesel generator set, and then the test should be carried out. Water tank leakage to check the method is often injected hot water, check its leaking place, but small leakage is not easy to find, can be used under the method just to check.


1. water pressure method inspection:


The heat dissipation tank each inlet and outlet hole is blocked, leaving only one inlet hole, with the hand pressure pump, the water from the inlet hole into the water tank, in (98.1-147) kPa pressure, continuous (3-5) min, check whether the joints or water pipe seepage and leakage phenomenon.


2. air pressure inspection:


Put the water tank flat in the tank filled with water, and then blow air to the air inlet, the pressure is in (49 ~ 98) kPa, pay attention to observe the water surface, if there is a crack can see a series of bubbles out of the water surface.


Water leaks are found after inspection and marked for repair. Water tank water pipe in the upper and lower water chamber joint welding leakage, polished clean, with a special soldering iron to melt solder. If the water tank outer water leakage, polished clean, coated with zinc oxide, with soldering iron repair. The heat sink that is crushed and deformed can be straightened with a special tool like a comb.


genset (2).jpg


Jiangsu Meao Power Technology Co., Ltd. focuses on the development and manufacture of diesel generator sets, and has accumulated rich experience in manufacturing and service in this field. As a professional generator manufacturer, MEAOPOWER attaches great importance to product development, innovation and service quality, and maintains close strategic cooperation with famous domestic and international enterprises such as Cummins, Perkins, Doosan, Yuchai, Weichai, Shangchai, Wuxi Wandi, Lillesomer, Stanford, Marathon and so on.